Protected Membrane Roof Assembly

Protected Membrane Roofing Membrane Roof Rigid Insulation Xps Insulation

Protected Membrane Roofing Membrane Roof Rigid Insulation Xps Insulation

Pin By Fields Roof Service On Single Ply Roofing Systems Xps Insulation Membrane Roof Insulation

Pin By Fields Roof Service On Single Ply Roofing Systems Xps Insulation Membrane Roof Insulation

One Of The Advantages Of Using Mm6125 In A Protected Membrane Roof Assembly Pmr Is That Once The Membrane Is Installed Owners In 2020 Membrane Roof Ballast Roofing

One Of The Advantages Of Using Mm6125 In A Protected Membrane Roof Assembly Pmr Is That Once The Membrane Is Installed Owners In 2020 Membrane Roof Ballast Roofing

Protected Membrane Roofing Stone Ballasting In 2020 Roofing Membrane Roof Ballast

Protected Membrane Roofing Stone Ballasting In 2020 Roofing Membrane Roof Ballast

Insulation Fiber Foamular Xps From Owens Corning Xps Insulation Insulation Membrane Roof

Insulation Fiber Foamular Xps From Owens Corning Xps Insulation Insulation Membrane Roof

Epdm Roof Detail Commercial Roofing Systems Roofing Systems Flat Roof Systems

Epdm Roof Detail Commercial Roofing Systems Roofing Systems Flat Roof Systems

Epdm Roof Detail Commercial Roofing Systems Roofing Systems Flat Roof Systems

This is intended to be only an illustration and must not be considered a suitable guideline governing the installation of the products.

Protected membrane roof assembly.

2 base membrane flashing carried vertically up a wall or parapet membrane flashing must extend up the vertical plane and above the finished roof waterproofing surface at least 200 mm 8 and must extend onto the roof field at least 100 mm 4 greater if. A blue roof can be created on a typical hydrotech pmr protected membrane roof assembly utilizing standard loose stone for ballast. Protected membrane roofing installation typical installation the following depicts the typical steps necessary to install hydrotech s monolithic membrane 6125 waterproofing roofing membrane assembly. One of the advantages of using mm6125 in a protected membrane roof assembly pmr is that once the membrane is installed owners and designers can take advantage of various ballast options gravel pavers and garden roof to suit a specific project s needs.

The insulation may be exposed to water so it should have minimal water absorption characteristics. Epdm pvc or tpo and has been loose laid the sheets can be most likely be cleaned up enough to be sent back to the factory and reformed into lower performance products such as parking curbs or roof walk pads. Extruded polystyrene xps is the most suitable type. It is the simplest blue roof that can be created.

Placed on top of hydrotech s monolithic membrane 6125 it offers protection from the harsh roof environment. Ballast options and flexibility. It is the simplest blue roof that can be created. Although the theory of a pmra assembly can be adapted many ways the most common form consists of a roof deck a directly adhered or loose laid roof membrane a loose laid extruded expanded polystyrene a loose laid.

This arrangement of roofing materials roof deck waterproofing membrane moisture resistant insulation is commonly referred to today as the protected membrane roof pmr or insulated roof membrane assembly irma. A blue roof can be created on a typical hydrotech pmr protected membrane roof assembly utilizing standard loose stone for ballast. Protected membrane roofing installation typical installation the following depicts the typical steps necessary to install hydrotech s monolithic membrane 6125 waterproofing roofing membrane assembly. This is intended to be only an illustration and must not be considered a suitable guideline governing the installation of the products.

The primary distinction of a protected membrane roof assembly pmra is that the roof insulation is placed on top of the membrane. Using standard ballast stone the water in the blue roof is stored within the void spaces of the stone and to the required level above the ballast. A horizontal poured in place concrete substrate. Protected membrane roof pmr in a protected membrane roof also known as an inverted roof membrane assembly irma the insulation is installed on top of the membrane.

A horizontal poured in place concrete substrate. 1 work included 1 base membrane field see tables 9 1 and 9 2 for acceptable membrane types and application methods.

Single Ply Roofing What Architects Should Ask Before They Specify Many Of The Modern Single Ply Roofing Single Ply Roofing Roofing Systems Flat Roof Systems

Single Ply Roofing What Architects Should Ask Before They Specify Many Of The Modern Single Ply Roofing Single Ply Roofing Roofing Systems Flat Roof Systems

Insulation Fiber Foamular Xps From Owens Corning Xps Insulation Corning Insulation

Insulation Fiber Foamular Xps From Owens Corning Xps Insulation Corning Insulation

Hydroguard In 2020 Membrane Roof Ballast Roofing

Hydroguard In 2020 Membrane Roof Ballast Roofing

Roofing Tips You Can Put Into Practice Today With Images Flat Roof Insulation Roof Insulation Flat Roof

Roofing Tips You Can Put Into Practice Today With Images Flat Roof Insulation Roof Insulation Flat Roof

Source : pinterest.com